| Sign In | Join Free | My adobecards.com |
|
Brand Name : GFUVE
Model Number : GF302D
Place of Origin : BEIJING,CHINA
MOQ : 1SET
Payment Terms : T/T, Western Union, MoneyGram
Supply Ability : 1500SETS/MONTH
Delivery Time : 1-2WEEKS
Packaging Details : CARTON
ACCURACY : 0.05%, 0.1%
POWER SUPPLY : One Phase AC 180-265V, frequency 50/60Hz
VOLTAGE RANGE : 57.7V, 100V, 220V, 380V or 69.3V, 120V, 240V, 480V( optional)
CURRENT RANGE : 200mA, 1A, 5A, 20A, 100A
FREQUENCY : 45Hz-65Hz
HARMONIC : 2-51times
DIMENSION : 500x600x175MM
WEIHGT : About 27KG
HARMONIC CONTENT : 0-40%
OUTPUT LOAD : each phase 25VA
| Electrical parameters | |
|---|---|
| Accuracy | 0.05%, 0.1% |
| Power Supply | One Phase AC 180-265V, frequency 50/60Hz. |
| AC Voltage Output | |
| Range(U1,U2,U3) | 57.7V, 100V, 220V, 380V or 69.3V, 120V, 240V, 480V( optional) |
| Adjustment range | (0-120)%RG(1) |
| Adjustment fineness | 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. |
| Stability | 0.01%/120s |
| Distortion | 0.3% (Non-capacitive load) |
| Output load | each phase 25VA |
| Measuring accuracy | 0.05%RG |
| AC Current Output | |
| Range(I1,I2,I3) | 200mA, 1A, 5A, 20A, 100A |
| Adjustment range | (0-120)%RG |
| Adjustment fineness | 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. |
| Stability | <0.01%/120s |
| Distortion | ≤0.3% (Non-capacitive load) |
| Output load | 45VA |
| Accuracy | 0.05%RG |
| Power Output | |
| Active power output stability | <0.01%RG/120s |
| Reactive power output stability | <0.02%RG/120s |
| Active power measuring accuracy | 0.05%RG |
| Reactive power measuring accuracy | 0.1%RG |
| Phase Output | |
| Output adjustment range | 0°-359.999° |
| Output adjustment fineness | 10, 1, 0.1, 0.01 as optional. |
| Resolution | 0.01° |
| Accuracy | 0.05° |
| Power Factor | |
| Adjustment range | -1 ~ 0 ~ 1 |
| Resolution | 0.0001 |
| Measurement accuracy | 0. 0005 |
| Frequency Output | |
| Adjustment range | 45Hz-65Hz |
| Output adjustment fineness | 5Hz, 1Hz, 0.1Hz, 0.01Hz as optional. |
| Resolution | 0.001Hz |
| Accuracy | 0.005Hz |
| Voltage /Current/Harmonic Setting | |
| Harmonic number | 2-51times |
| Harmonic content | 0-40% |
| Harmonic phase | 0-359.99 |
| Harmonic setting accuracy | (10%±0.1%)RD(2) |
| Power Energy Measurement Error | |
| Active power energy | 0.05%RG |
| Reactive power energy | 0.1%RG |
| Power Pulse Output | |
| Power pulse type | active pulse, reactive pulse |
| Active power pulse output | 5V, 10mA |
| Power Pulse Input | |
| Energy pulse type | support active and reactive pulse, the highest frequency power pulse input is 180K. |
| Mechanical parameters | |
| Dimensions (W×D×H) (mm) | 500x600x175 |
| Weight (kg) | About 27 |
|
|
Electromechanical Energy Meter Test Bench Settable 25VA AC180V Images |